Sill Sealer

Air and Moisture Barrier Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Made from ribbed polyethylene foam, Reflectix®…

Attic

…excellent, energy-efficient choice for upgrading an attic system. When installed properly, a reduction of up to 10% in the home’s air conditioning usage can result. The products are clean, lightweight…

Duct Insulation R-4.2

R-4.2 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Duct Insulation is an alternative to other types…

Duct Insulation R-5.6

…choice when selecting insulation for round or rectangular ductwork in HVAC systems. The product provides an R-5.6 when installed with a 0.375” air gap between the duct and the insulation….

Big Bubble Duct Insulation R‑6.0

R-6.0 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Duct Insulation is an alternative to other types…

Duct Insulation Outdoor R‑5.6

the first choice when selecting insulation for outdoor round or rectangular ductwork. The product provides an R-5.6 when installed with a 0.375” air gap between the duct and the insulation….

Duct Insulation Outdoor R‑8.0

…when selecting insulation for outdoor round or rectangular ductwork. The product provides an R-8.0 when installed with two 0.75” air gaps between the duct and two layers of the insulation….

Metal Building – Roof – Retrofit

…of 1.32 UP and 4.55 DOWN for interior air film. Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer….

Metal Building – Wall – New

Metal Interior with a 3/4” Thermal Break: R-8.2 Open Interior with a 3/4” Thermal Break: R-6.0 Metal Interior with a Nominal 3/4” Drape in Product (No Thermal Break): R-5.9 Open…

Post Frame Building – Roof – New

…energy that ordinarily would be transmitted to the interior of the building is blocked. * Includes thermal resistance of 1.32 UP and 4.55 DOWN for interior air film. Note: Installation…

Post Frame Building – Roof – Retrofit – Bottom of Purlin

…ordinarily would be transmitted to the interior of the building is blocked. * Includes thermal resistance of 1.32 UP and 4.55 DOWN for interior air film. Note: Installation instructions and…

Post Frame Building – Roof – Retrofit – Bottom of Truss

…resistance of 1.32 UP and 4.55 DOWN for interior air film. Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the

Post Frame Building – Roof – New

Below the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Above the Purlins Open Interior R-3.8* Heat Flow Down | R-3.5* Heat Flow Up Note: Installation…

Post Frame Building – Roof – Retrofit – Bottom of Purlin

Bottom of the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are…

Post Frame Building – Roof – Retrofit – Bottom of Truss

Bottom of the Trusses Open Interior R-6.6* Heat Flow Down | R-3.0* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are…

HVAC/R Literature and Submittals

…Submittal Revised 102022 F58 – Rad Fl Wood Joists Submittal Revised 102022 F44 – Reflectix RAP Return Air Panning Bubble Submittal Revised 102022 N38 – Reflectix RAP Return Air Panning…

Attic

…upgrading your attic system. When installed properly, a reduction of up to 10% in the home’s air conditioning usage can result. The products are clean, lightweight and easy to install….

Work Shop

Roof – Radiant Barrier Wall – Masonry R-3.7 and R-7.0 Wall – 2” x 4” R-6.6 (No Fiberglass) Wall – 2” x 4” R-14 Total Assembly (R-3.9 and a Vapor/Moisture…

Water Heater

R-4.5 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. This application is a great option for the Do-It-Yourselfer…

Products

…Spacers Expansion Joint Pipe Wrap Insulation Radiant Barrier (Reflective/Woven Fabric/Reflective) Return Air Duct Panning (Bubble) Return Air Duct Panning (Corrugate) Sill Sealer Single Reflective Insulation Tapes: Foil and White Poly…

Wall – Exterior (2 x 6)

R-21 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the

Wall – Exterior (2 x 4)

R-14 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the

Storage Building

Roof – Radiant Barrier Wall – Masonry R-3.7 and R-7.0 Wall – 2” x 4” R-6.6 (No Fiberglass) Wall – 2” x 4” R-14 Total Assembly (R-3.9 and a Vapor/Moisture…

Crawl Space R-21

R-21 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix is now offering a dramatically improved performance application…

Basement Ceiling

R-16 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. When considering options for a basement ceiling, Reflectix® Reflective/Bubble…

Metal Building – Roof – New

Open Interior with 3/4” Thermal Breaks R-5.5* Heat Flow Down R-3.4* Heat Flow Up Open Interior without Thermal Breaks and a Nominal 3/4” Drape R-4.0* Heat Flow Down R-3.2* Heat…

Metal Building – Roof – Retrofit

Open Interior with 1”x 2” Furring R-7.5* Heat Flow Down R-3.6* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the

Duct Insulation (Big Bubble)

…Insulation provides an R-8.0 when installed with a 0.75” air gap between the duct and insulation, and R-6.0 when installed direct to the duct without a spacer. Please refer to…

Wall – Exterior (2 x 6)

R-21 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the

Wall – Exterior (2 x 4)

R-14 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the

Post Frame Building – Wall – New

Inside the Girts Open Interior: R-4.2 Outside the Girts Open Interior: R-3.7 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of…

Post Frame Building – Wall – Retrofit

Inside the Girts Open Interior: R-4.2 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Insulation products are…

Crawl Space R-21

R-21 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix is now offering a dramatically improved performance application…

Kevin Thompson Retires After 33 Years of Faithful Service to Reflectix

…career with Reflectix began in June of 1989 as the Shipping Manager. Then after Sealed Air Corp acquired the company in 2000, he moved to the position of Plant Manager….

Snow Melt System

Increased Efficiency in a Snow Melt System Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. For the Do-It-Yourselfer,…