Metal Building – Roof – New

Open Interior with 3/4” Thermal Breaks R-10* Heat Flow Down (and a Radiant Barrier) R-4.5* Heat Flow Up Open Interior without Thermal Breaks and a Nominal 3/4” Drape R-7.6* Heat…

Post Frame Building – Wall – New

Inside the Girts Metal Interior: R-6.3 Open Interior: R-5.3 Outside the Girts Metal Interior: R-5.5 Open Interior: R-4.7 Note: Installation instructions and illustrated drawings are recommendations only, while proper local…

Post Frame Building – Wall – Retrofit

Inside the Girts Metal Interior: R-6.3 Open Interior: R-5.3 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix®…

Post Frame Building – Roof – New

Below the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Above the Purlins Open Interior R-3.8* Heat Flow Down | R-3.5* Heat Flow Up Note: Installation…

Wall – Masonry

R-3.7, R-7.0 and a Vapor/Moisture Barrier Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. The Do-It-Yourselfer has several…

Wall – Exterior (2 x 6)

R-21 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…

Post Frame Building – Roof – Retrofit – Bottom of Purlin

Bottom of the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are…

Wall – Exterior (2 x 4)

R-14 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…

Post Frame Building – Roof – Retrofit – Bottom of Truss

Bottom of the Trusses Open Interior R-6.6* Heat Flow Down | R-3.0* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are…

Radiant Floor – Wood Joists

Up to R-21 and a Radiant Reflector (Maximum Benefit Application) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer….

Reflectix is FANTASTIC!

I am building a greenhouse and am using Reflectix on the north wall for insulating and for the reflection of the sun. I’ve used many products that do not perform…

Post Frame Building – Wall – New

Inside the Girts Open Interior: R-4.2 Outside the Girts Open Interior: R-3.7 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of…

Knee Wall

R-16 and a Radiant Reflector (with R-13 Fiberglass Batt) R-19 and a Radiant Reflector (with R-13 Fiberglass Batt and 0.75” Furring (on Back of Knee Wall)) Note: Installation instructions and…

Post Frame Building – Wall – Retrofit

Inside the Girts Open Interior: R-4.2 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Insulation products are…

Work Shop

Roof – Radiant Barrier Wall – Masonry R-3.7 and R-7.0 Wall – 2” x 4” R-6.6 (No Fiberglass) Wall – 2” x 4” R-14 Total Assembly (R-3.9 and a Vapor/Moisture…

Wine Room

R-3.7 (1” x 2” Furring with 1 Air Space) R-7.0 (2” x 2” Furring with 2 Air Spaces in Addition to a Vapor/Moisture Barrier) Note: Installation instructions and illustrated drawings…

Wall – Masonry

R-3.7, R-7.0 and a Vapor/Moisture Barrier Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. The Do-It-Yourselfer has several…

Wall – Exterior (2 x 6)

R-21 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…

Wall – Exterior (2 x 4)

R-14 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…

Storage Building

Roof – Radiant Barrier Wall – Masonry R-3.7 and R-7.0 Wall – 2” x 4” R-6.6 (No Fiberglass) Wall – 2” x 4” R-14 Total Assembly (R-3.9 and a Vapor/Moisture…

Radiant Floor – Wood Joists

Up to R-21 and a Radiant Reflector (Maximum Benefit Application) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer….

Pipe Wrap

R-2.0 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Reflective/Bubble products for pipe wrap applications are the…

Knee Wall

R-16 and a Radiant Reflector (with R-13 Fiberglass Batt) R-19 and a Radiant Reflector (with R-13 Fiberglass Batt and 0.75” Furring (on Back of Knee Wall)) Note: Installation instructions and…

Garage Door

R-3.0 (Also Provides a Radiant Barrier Benefit in Warmer Climates) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer….

Duct Insulation R-6.0

R-6.0 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Utilizing Reflectix® to enhance the efficiency of your existing…

Duct Insulation R-4.2

R-4.2 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Utilizing Reflectix® to enhance the efficiency of your existing…

Behind Hot Water Radiator

R-3 and a Radiant Reflector Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. In order to increase the…

Agricultural / Livestock Buildings

Poultry Houses Stables Dairy / Milking Facilities Hog Farms Reflectix offers a wide range of applications and products for installation in Agricultural and Livestock Buildings. Depending on the structure of…

Radiant Floor – In a Subfloor

R-4.6 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® has an insulating upgrade available for a radiant…

Radiant Floor – Over an Existing Floor

R-1.1 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® has an insulating upgrade available for a radiant…

Sill Sealer

…Reflectix® Sill Sealer was designed to reduce air leakage between the foundation wall and sill plate. The Sill Sealer can also be used to seal around window and door frames….

RV Applications

I am a full time RVer. I live in my 35 ft. Jayco camper year-round. I use Reflectix in the winter months to keep the warm air in and in…

A Happy Camper!

…it’s use, even doing test studies on your product. It’s now being used by hammock campers, as a means of keeping warm while hanging out in the open, suspended between…

A 25 Year Old Roll of Reflectix Tape

This is just a note about a recent use of Reflectix tape. The unusual thing about it is that this tape is at least 25 years old, but still has…

Expansion Joint

Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. This durable, lightweight, closed-cell, foam expansion joint is the solution…