Search Results

Search results for “Ukraine International Airlines Flight 1-800-299-7264 Booking Phone Number Reservations 800”

Privacy Policy

…may also be revealed: your name, e-mail address, home and work addresses, telephone and fax numbers and any plain text commentary. Additionally, the complete record of your actions at the…

RIMA International Offers a Reflective Technology Seminar at METALCON 2011

Olathe, KS – The Reflective Insulation Manufacturers Association International (RIMA-I) will be presenting an educational training session entitled “Fundamentals of Reflective Technology” at the 2011 METALCON show in Atlanta, Georgia….

First Alexander Schwartz Award Presented

…papers, book chapters and presentations Research in building science and materials at the Oak Ridge National Laboratory Contributing leader of RIMA, ASTM, the International Vacuum Insulation Symposium, the International Thermal…

2018 I-RIM Conference Costa Rica a Great Success!

…of the presentations, please visit https://www.rimainternational.org/i-rim-conference/2018-i-rim-conferencecosta-rica/. The Reflective Insulation Manufacturer’s Association International is a group of dedicated people working together to propagate the knowledge and use of reflective insulations and…

Frequently Asked Questions

…benefit. What is an R-value? An R-value is an assigned number derived from a specific testing procedure (or calculation) to determine a material’s (or building assemblage) “resistance to conductive heat…

Performance Information

…conjunction with an air space, it provides a quantifiable R-value level of benefit. What is an R-value? An R-value is an assigned number derived from a specific testing procedure (or…

RIMA-I Bestows Special Award To Monty Millspaugh

Olathe, KS – The Reflective Insulation Manufacturers Association International (RIMA-I) has named Monty Millspaugh of Reflectix Inc. as the recipient of the 2022 Alexander Schwartz Award. The honor was present…

Contact Information

Location: #1 School Street, Markleville, IN 46056 Mailing Address: Reflectix, Inc., P.O. Box 108, Markleville, IN 46056 Social Media: vimeo.com/user175013284 www.youtube.com/ReflectixInsulation www.facebook.com/ReflectixInsulation www.linkedin.com/company/reflectix-inc Email: customerservice@reflectixinc.com Phone: (765) 533-4332 or (800)…

Duct Insulation Spacers

…ASTM International RIMA-I Verification Program for Reflective Insulative Materials.           About the Product: The Reflectix® Duct Insulation Spacers are for use in conjunction with the Reflectix®…

ASTM / RIMA-I Verification Program – Press Release

…third-party certification program providers in the country, and an affiliate of ASTM International. It gives Reflectix great pride to feature the ASTM International/RIMA-I Verification Program logo on those products, that…

ASTM / RIMA-I Verification Program – Press Release

…third-party certification program providers in the country, and an affiliate of ASTM International. It gives Reflectix great pride to feature the ASTM International/RIMA-I Verification Program logo on those products, that…

What About R-values?

What is an R-value? An R-value is an assigned number derived from a specific testing procedure (or calculation) to determine a materials (or building assemblage) “resistance to conductive heat transfer”….

Crawl Space R-21

R-21 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix is now offering a dramatically improved performance application…

Crawl Space R-21

R-21 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix is now offering a dramatically improved performance application…

Trade Shows & Events

…North American Meeting: October 14 – 17 / Chicago, IL Pack Expo International: November 3 – 6 / Chicago, IL Hardi Annual Conference: December 7 – 10 / Atlanta, GA…

The Reflectix 2022 Trade Show Schedule

…Denver, CO AD North American Meeting: October 17 – 20 / Kissimmee, FL Blue Hawk Fall Advisory Forum: October 24 – 26 / Location TBD Pack Expo International: October 23…

Kevin Thompson Retires After 33 Years of Faithful Service to Reflectix

…He also served many years as Management Rep for the company’s ISO quality management system which provides a certification with an international accreditation to confirm our commitment to quality to…

Duct Insulation (Indoor and Outdoor)

Pictured: Top 4 Images – Indoor Duct Insulation, Bottom 4 Images – Outdoor Duct Insulation The Indoor Duct Insulation has been evaluated for/and meets the requirements of the ASTM International

Options for the Retailer

…Qualified when installed in Walls, Crawls and Attics Product Testing Certified by the Reflective Insulation Manufacturers Association – International Product Testing Performed by R&D Services Double Reflective Insulation – Standard…

Crawl Space R-21

R-21 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. When considering options for a crawl space, Reflectix® Double…

Reflectix® RAP (Bubble) Return Air Duct Panning

Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® RAP (Bubble) is an alternative to conventional sheet metal…

Reflectix® RAP (Corrugated Sheet) Return Air Duct Panning

Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® RAP (Corrugated) is an alternative to conventional sheet metal…

Reflectix History 101

…the International Organization for Standardization. To achieve and hold this ISO classification, Reflectix submits to twice-a-year, outside audits of our quality system. This ensures the highest possible and consistent quality…

Attic

Radiant Barrier Note: This is an example of 1 of 3 installation methods. Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility…

Cathedral Ceiling

Northern Zone of the USA – With Reflectix® Below the Mass Insulation: R-7.0 Summer & R-1.0 Winter and a Vapor/Moisture Barrier Southern Zone of the USA – With Reflectix® Above…

Attic

Radiant Barrier Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® products are an excellent, energy-efficient choice for…

Cathedral Ceiling

Northern Zone of the USA – With Reflectix® Below the Mass Insulation: R-7.0 Summer & R-1.0 Winter and a Vapor/Moisture Barrier Southern Zone of the USA – With Reflectix® Above…

Attic

Radiant Barrier Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® products are an excellent, energy-efficient choice for…

Post Frame Building – Wall – New

Inside the Girts Metal Interior: R-6.3 Open Interior: R-5.3 Outside the Girts Metal Interior: R-5.5 Open Interior: R-4.7 Note: Installation instructions and illustrated drawings are recommendations only, while proper local…

Post Frame Building – Wall – Retrofit

Inside the Girts Metal Interior: R-6.3 Open Interior: R-5.3 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix®…

Post Frame Building – Roof – New

Below the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Above the Purlins Open Interior R-3.8* Heat Flow Down | R-3.5* Heat Flow Up Note: Installation…

Wall – Masonry

R-3.7, R-7.0 and a Vapor/Moisture Barrier Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. The Do-It-Yourselfer has several…

Wall – Exterior (2 x 6)

R-21 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…

Post Frame Building – Roof – Retrofit – Bottom of Purlin

Bottom of the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are…

Wall – Exterior (2 x 4)

R-14 Total Assembly (R-3.9 and a Vapor/Moisture Barrier for the Reflectix®) Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the…