…Privacy Policy changes Privacy rights of California residents Other websites Social plug-ins Contacting us WHAT INFORMATION IS COLLECTED BY REFLECTIX? Any time you complete a contact form, or introduce or…
Search Results
Search results for “Open 1-800-299-7264 Sun Country Airlines contact number”
Privacy Policy
Small Project Roll Applications
“My kids joke that my hobbies are recycling and insulating, but it’s no joke!” — Ellen B., Albuquerque, NM — Reflectix® Reflective/Bubble product excels in a wide variety of…
Hobby Roll Applications
“My kids joke that my hobbies are recycling and insulating, but it’s no joke!” — Ellen B., Albuquerque, NM — Reflectix® Reflective/Bubble product excels in a wide variety of…
Frequently Asked Questions
…insulation benefit is derived from the interaction of the highly-reflective surface with the air space. If the reflective surface is in contact with another building material, it becomes a conductor…
Performance Information
…surface is in contact with another building material, it becomes a conductor (transmitting the energy by conduction). An air space may be specified on one or both sides of the…
Metal Building – Roof – New
Open Interior with 3/4” Thermal Breaks R-5.5* Heat Flow Down R-3.4* Heat Flow Up Open Interior without Thermal Breaks and a Nominal 3/4” Drape R-4.0* Heat Flow Down R-3.2* Heat…
Metal Building – Roof – New
Open Interior with 3/4” Thermal Breaks R-10* Heat Flow Down (and a Radiant Barrier) R-4.5* Heat Flow Up Open Interior without Thermal Breaks and a Nominal 3/4” Drape R-7.6* Heat…
Contact Us
Contact Information
Location: #1 School Street, Markleville, IN 46056 Mailing Address: Reflectix, Inc., P.O. Box 108, Markleville, IN 46056 Social Media: vimeo.com/user175013284 www.youtube.com/ReflectixInsulation www.facebook.com/ReflectixInsulation www.linkedin.com/company/reflectix-inc Email: customerservice@reflectixinc.com Phone: (765) 533-4332 or (800)…
ASTM / RIMA-I Verification Program – Press Release
…third-party certification program providers in the country, and an affiliate of ASTM International. It gives Reflectix great pride to feature the ASTM International/RIMA-I Verification Program logo on those products, that…
ASTM / RIMA-I Verification Program – Press Release
…third-party certification program providers in the country, and an affiliate of ASTM International. It gives Reflectix great pride to feature the ASTM International/RIMA-I Verification Program logo on those products, that…
Reflectix® RAP (Bubble) Return Air Duct Panning
Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® RAP (Bubble) is an alternative to conventional sheet metal…
Attic
…and easy to install. Additionally, attic-mounted HVAC ducts benefit from the reduction of attic surface temperatures. Note: Attic Radiant Barriers provide benefit on hot sunny days. For this reason, they…
Duct Insulation Spacers
…Duct Insulation. The spacers are easy to work with, and provide an enclosed air space between the duct and the insulation. The enclosed air space (and number of enclosed air…
What About R-values?
What is an R-value? An R-value is an assigned number derived from a specific testing procedure (or calculation) to determine a materials (or building assemblage) “resistance to conductive heat transfer”….
Post Frame Building – Wall – New
Inside the Girts Metal Interior: R-6.3 Open Interior: R-5.3 Outside the Girts Metal Interior: R-5.5 Open Interior: R-4.7 Note: Installation instructions and illustrated drawings are recommendations only, while proper local…
Post Frame Building – Roof – New
Below the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Above the Purlins Open Interior R-3.8* Heat Flow Down | R-3.5* Heat Flow Up Note: Installation…
Post Frame Building – Wall – New
Inside the Girts Open Interior: R-4.2 Outside the Girts Open Interior: R-3.7 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of…
Metal Building – Wall – New
Open Interior with a 3/4” Thermal Break: R-4.6 Open Interior with a Nominal 3/4” Drape in Product (No Thermal Break): R-3.7 Note: Installation instructions and illustrated drawings are recommendations only,…
Metal Building – Wall – New
Metal Interior with a 3/4” Thermal Break: R-8.2 Open Interior with a 3/4” Thermal Break: R-6.0 Metal Interior with a Nominal 3/4” Drape in Product (No Thermal Break): R-5.9 Open…
Post Frame Building – Roof – New
Below the Purlins Metal Interior R-11 Heat Flow Down (and a Radiant Barrier) | R-5.1 Heat Flow Up Open Interior R-9.0* Heat Flow Down (and a Radiant Barrier) | R-4.4*…
2018 I-RIM Conference Costa Rica a Great Success!
…event, presentations will be available for purchase (in PDF format) for $25/presentation or $200 for the full set. Contact RIMA-I at rima@rima.net for details or to place your order. We’d…
Post Frame Building – Wall – Retrofit
Inside the Girts Metal Interior: R-6.3 Open Interior: R-5.3 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix®…
Post Frame Building – Roof – Retrofit – Bottom of Purlin
Bottom of the Purlins Open Interior R-6.4* Heat Flow Down | R-3.7* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are…
Post Frame Building – Roof – Retrofit – Bottom of Truss
Bottom of the Trusses Open Interior R-6.6* Heat Flow Down | R-3.0* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are…
Post Frame Building – Wall – Retrofit
Inside the Girts Open Interior: R-4.2 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Insulation products are…
Reflectix® RAP (Corrugated Sheet) Return Air Duct Panning
Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® RAP (Corrugated) is an alternative to conventional sheet metal…
Metal Building – Roof – Retrofit
Open Interior with 1”x 2” Furring R-7.5* Heat Flow Down R-3.6* Heat Flow Up Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the…
Metal Building – Wall – Retrofit
Open Interior: R-3.5 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Insulation products are a technologically advanced…
Metal Building – Roof – Retrofit
Open Interior with 1”x 2” Furring R-11* Heat Flow Down (and a Radiant Barrier) R-4.4* Heat Flow Up Please Note: In addition to the stated R-value, this application also provides…
Metal Building – Wall – Retrofit
Open Interior: R-4.5 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Insulation products are a group of…
Post Frame Building – Roof – Retrofit – Bottom of Purlin
Bottom of the Purlins Metal Interior R-11 Heat Flow Down (and a Radiant Barrier) | R-5.1 Heat Flow Up Open Interior R-9.0* Heat Flow Down (and a Radiant Barrier) |…
Post Frame Building – Roof – Retrofit – Bottom of Truss
Bottom of the Trusses Open Interior R-10* Heat Flow Down (and a Radiant Barrier) | R-3.7* Heat Flow Up Please Note: In addition to the stated R-value, this application also…
Behind Hot Water Radiator
R-3 and a Radiant Reflector Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. In order to increase the…
Duct Insulation R-4.2
R-4.2 Note: Installation instructions and illustrated drawings are recommendations only, while proper local construction methods are the responsibility of the installer. Reflectix® Duct Insulation is an alternative to other types…